Hytrol Catalog

CATALOG | 08312018 SINGLE POWERED PIVOT DIVERTER CAPACITY –75 lbs. maximum package weight. PACKAGE SIZE –Minimum 6 in. wide x 9 in. long, maximum 12 in. wide x 21 in. long. NOTE: Small packages must not be top heavy. DIVERTER SPEED –AC Drive 42-420 FPM. DIVERTER MECHANISM –Two rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts. MOUNTING –Complete unit bolts to 138-ACC 13 in. to 22 in. BR only or 190-ACC 13 in. to 21 in. BR, RH or LH diversion 30˚ spur discharge (spur not included). Minimum elevation 15 in. (138-ACC) or 16 in. (190-ACC). NOTE : ACC belt must be opposite discharge side. Widths over 22 in. BR contact Factory. CYCLES –Up to 40 times per minute. DRIVE –1/2 HP motor with AC type variable speed controller. Select 230V–3 Ph. 60 Hz. or 115V–1 Ph. 60 Hz. power. AIR CYLINDER –1 1/4 in. dia. bore x 1 in. stroke, double acting with internal rubber bumpers both ends. AIR VALVE –Single solenoid 4-way valve with speed controls,1/4 in. NPT valve ports. Requires maintained electrical signal of 115V–1 Ph. 60 Hz. from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .09 amps holding. AIR REQUIREMENTS –Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .014 cu. ft. per cycle. NOTE : To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard). The Powered Pivot Diverter is designed for use with Models 138-ACC & 190-ACC Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines. 5-1/4" CENTERLINE OF DRIVEWHEEL SHAFT "ACC"DRIVEBELT FLOW FLOW 30˚ MIN.TODISCHARGE ENDOFSECTION 21" MIN.TO INFEED ENDOFSECTION 21" FLOW "ACC" DRIVE BELT L.H. SPUR R.H. DIVERTER L.H. DIVERTER R.H. SPUR • STANDARD SPECIFICATIONS SYSTEMS ACCESSORIES DOUBLE POWERED PIVOT DIVERTER The Double Powered Pivot Diverter is designed for use with Models 138-ACC & 190-ACC Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines. "ACC" DRIVE BELT R.H. SPUR L.H. SPUR L.H. DIVERTER R.H. DIVERTER 9" MIN. TO DISCHARGE END OF SECTION 21" MIN. TO INFEED END OF SECTION 21" FLOW 5-1/4" CENTERLINE OF DRIVEWHEEL SHAFT "ACC" DRIVE BELT FLOW FLOW 30˚ CAPACITY –75 lbs. maximum package weight. PACKAGE SIZE –Minimum 6 in. wide x 9 in. long maximum 34 in. wide x 46 in. long. NOTE: Small packages must not be top heavy. DIVERTER SPEED –AC Drive 42-420 FPM. DIVERTER MECHANISM –Four rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts. MOUNTING –Complete unit bolts to 138-ACC 13 in. to 22 in. BR only or 190-ACC 13 in. to 39 in. BR, RH or LH Diversion 30˚ spur discharge (spur not included). Minimum elevation 15 in. (138-ACC) or 16 in. (190-ACC). NOTE : ACC belt must be opposite discharge side. Widths over 22 in. BR, contact Factory. CYCLES –Up to 40 times per minute. DRIVE –1/2 HP motor with AC type variable speed controller. Select 230V–3 Ph. 60 Hz. or 115V–1 Ph. 60 Hz. power. AIR CYLINDER –1 1/4 in. dia. bore x 1 in. stroke, double acting with internal rubber bumpers both ends. AIR VALVE –Single solenoid 4-way valve with speed controls. 1/4 in. NPT valve ports. Requires maintained electrical signal of 115 V–1 Ph. 60 Hz. from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .09 amps holding. AIR REQUIREMENTS –Minimum pressure 60 P.S.I., maximum 125 P.S.I. Free air consumption at 60 P.S.I., .028 cu. ft. per cycle. NOTE : To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard). • STANDARD SPECIFICATIONS CATALOG | 08312018 SYSTEMS ACCESSORIES CAPACITY –75 lbs. maximum package weight. PACKAGE SIZE –Minimum 4 in. wide x 6 in. long, maximum 26 in. wide x 36 in. long. NOTE: Small packages must not be top heavy. NOTE: Product must be justified to divert side. DIVERTER SPEED – 50-200 FPM set on Motor Controller DIVERTER MECHANISM –Two rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts. MOUNTING –Bolts to 190-E24 15 in. to 39 in. BR, RH or LH diversion 30˚ spur discharge (spur not included). Minimum elevation 14 in. NOTE : O-rings must be opposite discharge side. Widths over 39 in. BR contact factory. CYCLES –Up to 40 times per minute. MOTOR –24 VDC motor, 3 amps per motor, one each Divert Bank. MOTOR CONTROLLER – Controls and Protects Motor, one each Divert Bank. AIR CYLINDER –1 1/4 in. dia. bore x 2 in. stroke, double acting with internal rubber bumpers both ends. AIR VALVE –Single solenoid 4-way valve with speed controls,1/8 in. NPT valve ports. Requires main- tained electrical signal of 24VDC watt from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .32 amps holding. AIR REQUIREMENTS –Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .064 cu. ft. per cycle. NOTE : To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard). CAPACITY –75 lbs. maximum package weight. PACKAGE SIZE –Minimum 4 in. wide x 6 in. long, maximum 26 in. wide x 36 in. long. NOTE: Small packages must not be top heavy. NOTE: Product must be justified to divert side. DIVERTER SPEED – 50-200 FPM set on Motor Controller DIVERTER MECHANISM –One row of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts. MOUNTING –Complete unit bolts to 190-E24 15 in. to 21 in. BR, RH or LH diversion 30˚ spur dis- charge (spur not included). Minimum elevation 14 in. NOTE : O-rings must be opposite discharge side. Widths over 39 in. BR contact factory. CYCLES –Up to 40 times per minute. MOTOR –24 VDC motor, 3 amps per motor, one each Divert Bank. MOTOR CONTROLLER – Controls and Protects Motor, one each Divert Bank. AIR CYLINDER –1 1/4 in. dia. bore x 2 in. stroke, double acting with internal rubber bumpers both ends. AIR VALVE –Single solenoid 4-way valve with speed controls,1/8 in. NPT valve ports. Requires main- tained electrical signal of 24VDC watt from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .32 amps holding. AIR REQUIREMENTS –Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .032 cu. ft. per cycle. NOTE : To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard). E24 SINGLE POWERED PIVOT DIVERTER ECN DWGNO DESIGNEDBY CHECKEDBY HYTROL JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL DATE DATE MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° 8/18/ THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC. DRAWNBY DATE8/19/ PAINTCLASS REVISION SPAREPART MFGCLASS C Catalog kchurchill kchurchill MIN. TO DISCHARGE END OF SECTION 4-1/2" MIN. TO INFEED END OF SECTION 7-1/2" ECN DWGNO DESIGNEDBY CHECKEDBY HYTROL JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL DATE DATE MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° 8/18/2011 THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC. DRAWNBY DATE8/19/2011 PAINTCLASS REVISION SPAREPART MFGCLASS C Catalog-Int kchurchill kchurchill • STANDARD SPECIFICATIONS E24 DOUBLE POWERED PIVOT DIVERTER The Double Powered Pivot Diverter is designed for use with Models 190-E24 & 190-E24EZ Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines. • STANDARD SPECIFICATIONS ECN DWGNO DESIGNEDBY CHECKEDBY HYTROL JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL DATE DATE MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° 8/18/2011 THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC. DRAWNBY DATE8/19/2011 PAINTCLASS REVISION SPAREPART MFGCLASS C Catalog-Int kchurchill kchurchill ECN DWGNO DESIGNEDBY CHECKEDBY HYTROL JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL DATE DATE MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° 8/18/2011 THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC. DRAWNBY DATE8/18/2011 PAINTCLASS REVISION SPAREPART MFGCLASS C Catalog60inch-Int kchurchill kchurchill MIN. TO DISCHARGE END OF SECTION 7-1/2" 6 MIN. TO INFEED END OF SECTION 7-1/2" ECN DWGNO DESIGNEDBY CHECKEDBY HYTROL JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL DATE DATE MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° 8/18/2011 THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC. DRAWNBY DATE8/18/2011 PAINTCLASS REVISION SPAREPART MFGCLASS C Catalog kchurchill kchurchill ECN DWGNO DESIGNEDBY CHECKEDBY HYTROL JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL DATE DATE MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° 8/18/2011 THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC. DRAWNBY DATE8/18/2011 PAINTCLASS REVISION SPAREPART MFGCLASS C Catalog kchurchill kchurchill RH Spur RH Spur LH Spur LH Spur RH Diverter LH Diverter The Powered Pivot Diverter is designed for use with Models 190- E24 & 190-E24EZ Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines. RH Diverter LH Diverter

RkJQdWJsaXNoZXIy NjQ0OTEy