Hytrol Catalog

CATALOG | 08312018 AUXILIARY COMPONENTS Auxiliary I/O Module Plugs into auxiliary port of any controller - used to provide photo eye output or to accept a voltage type input. 032.532 Auxiliary Input Cable Attaches to any zone controller. Used for zone stop input, wakeup eye input, or slug input. Available in 3 and 10 ft. lengths. 3 ft. ....................................................... 032.563 10 ft......................................................... 032.564 Zone Actuation Module“ZAM”(Alternate Drive) Provides NPN, PNP, or dry contact output from zone controller. 032.531 Retro-ReflectiveWake-up Eye Plugs into auxiliary port of any controller to send wake-up signal. 032.591 DiffuseWake-up Eye Plugs into auxiliary port of any controller to send wake-up signal. 032.592 Retro-Reflectors 2.18”Dia. ...............................................032.218 3”Dia. ..................................................... 032.2185 Connector Covers Upstream Connector Cover ...................... 032.010 Downstream Connector Cover ................032.011 CABLE COMPONENTS Power Isolation Cable Required to isolate DC power when joining conveyors w/ separate IOPs utilizing no more than one set of I/O boards. Standard Push-On ..................................032.562 IOP Isolation Cable Required to isolate DC power and input/output signals when joining two conveyors with separate IOPs, both utilizing I/O boards. Standard Push-On ..................................032.570 Extension Cable (Zone to Zone Communication) Available in 3 and 10 ft. lengths. Used to extend zone controller cable when necessary. Standard Push-On 3 ft. ..........................032.560 Standard Push-On 10 ft. .........................032.561 Push-On Type Cable NOTE : All GEN3 EZLogic® Components are List Price. EZLOGIC ® COMPONENTS CATALOG | 08312018 CABLE COMPONENTS (continued) Nano Extension Cable Used to extend auxiliary devices or remote transducer cable. Available in the following lengths: 1 ft ..........................................................032.565 2 ft. .........................................................032.566 3 ft. .........................................................032.567 6 ft. .........................................................032.568 Power Splitter Used to connect two conveyors located side by side to one IOP. Requires 2 power supply T cables. Maximum total of 50 zones. 032.569 SPECIAL USE COMPONENTS Diffuse Type Zone Controller Zone controller including mounting base and unitized diffuse transducer with adjustable sensitivity (through programming). 24 in. cable. 032.503 Remote Retro-Reflective Transducer Attaches to any remote zone controller and allows transducer to be mounted separate from controller. 032.511 Remote Diffuse Transducer Attaches to any remote zone controller and allows transducer to be mounted separate from controller. 032.512 Remote Retro-Reflective Transducer (Dual with T Cable) For use in dual head applications. Attaches to any remote zone controller and allows addition of second remote transducer. 032.514 Remote Diffuse Transducer (Dual with T Cable) For use in dual head applications. Attaches to any remote zone controller and allows addition of second remote transducer. 032.515 Remote Diffuse Transducer (Narrow Beam, Dual with T Cable) For use in dual head applications. Has narrow beam for use with close roller centers. Attaches to any remote zone controller and allows addition of second remote transducer. 032.516 NOTE : All GEN3 EZLogic® Components are List Price. EZLOGIC ® COMPONENTS

RkJQdWJsaXNoZXIy NjQ0OTEy